VT-3Vacuum TubeInstrument InterfaceD.W. FEARNOperating Instructions

Strany 2 - How to Contact us:

D.W. FEARNVT-I/F Vacuum Tube Instrument Interface11DescriptionThe D.W. Fearn model VT-3 Vacuum Tube DI is designed to provide recordingprofessionals w

Strany 3 - Table of Contents

13InstallationThe VT-3 is carefully packed for shipment and should survive all but the mostbrutal handling. If there is any damage, keep the shipping

Strany 4

VT-I/F Vacuum Tube Instrument InterfaceD.W. FEARN14are required. The ground pin of the power cord is internally connected to the chas-sis. This confi

Strany 5 - LIMITED 5-YEAR WARRANTY

D.W. FEARNVT-I/F Vacuum Tube Instrument Interface15connectors at all times. It is not good practice to use both the front and rear con-nectors at the

Strany 6

VT-I/F Vacuum Tube Instrument InterfaceD.W. FEARN16Grounding and ShieldsA full discussion of proper studio wiring schemes is beyond the scope of thism

Strany 7

17OPERATIONFRONT PANEL CONTROLS (see Figure 2)Power switch (11)Primary power is applied to the VT-3 circuits when the Power switch (11) is inthe up po

Strany 8 - Specifications

VT-I/F Vacuum Tube Instrument InterfaceD.W. FEARN18Fluorescent lights and SCR dimmers are terrible electrical noise generators.Turn off the fluorescen

Strany 9

D.W. FEARNVT-I/F Vacuum Tube Instrument Interface191. The VT-3 must be located near the instrument. Ten feet of cable between theinstrument and the VT

Strany 11 - Installation

21THEORY OF OPERATIONThis circuit description refers to only one channel. Both channels are identical,sharing only the power supply. (See Figure 3.)I

Strany 12

How to Contact us:Telephone: 610-793-2526Fax: 610-793-1479Mail: P.O. Box 57, Pocopson, PA 19366 U.S.A.Shipping Address:182 Bragg Hill RoadWest Chester

Strany 13

VT-I/F Vacuum Tube Instrument InterfaceD.W. FEARN22The GND LIFT switch disconnects pin 1 of the OUTPUT connector from theinternal ground when the swit

Strany 14

D.W. FEARNVT-I/F Vacuum Tube Instrument Interface23MAINTENANCEThe VT-3 is built with only the highest quality parts and will prove to beextremely reli

Strany 15 - OPERATION

VT-I/F Vacuum Tube Instrument InterfaceD.W. FEARN24microphonic response above -55 dBm is excessive. Replacement is indicatedunless the VT-3 always ope

Strany 16

D.W. FEARNVT-I/F Vacuum Tube Instrument Interface25repair experience, you may return the VT-3 to the factory for repair. Call first,however, for shipp

Strany 17

Table of ContentsHistory of the VT-3 ... 7Specifications...

Strany 18

NoticeD.W. Fearn shall not be liable for technical or editorial errors or omissions in this manual, norfor incidental or consequential damages resulti

Strany 19 - Mic Level Output

LIMITED 5-YEAR WARRANTYDuring the warranty period, D.W. Fearn will, at no additional charge, repair or replace defective partswith new parts.This warr

Strany 20

7History of the VT-3 Vacuum Tube DIAs far back as I can remember, taking instruments “direct” has never soundedvery good to me. There always seemed to

Strany 21 - MAINTENANCE

VT-I/F Vacuum Tube Instrument InterfaceD.W. FEARN8This prototype was evaluated by a number of studio friends, who made someuseful suggestions. These s

Strany 22

D.W. FEARNVT-I/F Vacuum Tube Instrument Interface9Specifications(with 200 mV input)Input 200 mV nominalunbalancedInput LoadImpedance 1 megohm minimu